| Performance |
AC5124-10
|
AC5124-200
|
| Interface |
40-pin mini connector
|
40-pin mini connector
|
Interface
Data Rate
(standard PC Baud Rates) |
Up to 115.2 Kbps
|
Up to 115.2 Kbps
|
Interface
Data Rate
(nonstandard PC Baud Rates) |
882 Kbps
|
882 Kbps
|
| Power
Consumption (typical) |
123 mA TX
100 mA RX
25 mA sleep mode
|
280 mA TX
110 mA RX
25 mA sleep mode
|
Channels
(to create independent networks) |
77
|
77
|
| Security |
User assigned system ID;
Unique IEEE address
|
User assigned system ID;
Unique IEEE address
|
| Radio Frequency |
AC5124-10
|
AC5124-200
|
| Frequency
Band |
2.402 - 2.478 GHz
|
2.402 - 2.478 GHz
|
| Radio
Type |
FHSS
|
FHSS
|
| Output
Power |
10 mW typical
|
200 mW typical
|
| Voltage |
5 V nominal +/- 2%
+/- 50 mV ripple
|
5 V nominal +/- 2%
+/- 50 mV ripple
|
| Sensitivity |
-90dBm typical
|
-90dBm typical
|
| RF
Baud Rate |
882 Kbps
|
882 Kbps
|
Range
(typical;
depends on antenna/environment) |
Up to:
300 ft indoors
3,000 ft line-of-sight
|
Up to:
500 ft indoors
10,000 ft line-of-sight
|
| PLL
Lock Time |
500 us typical
|
500 us typical
|
| Environmental |
AC5124-10
|
AC5124-200
|
| Temperature
(operating) |
-40°
to +80° C
|
-40°
to +80° C
|
| Temperature
(storage) |
-50°
to +85° C
|
-50°
to +85° C
|
| Humidity
(non-condensing) |
10% to 90%
|
10% to 90%
|
| Physical |
AC5124-10
|
AC5124-200
|
| Dimensions |
1.65 x 2.65 x 0.20 inches
(6.7 x 4.2 x 0.5 cm);
Integral dipole add 0.46 inch (1.2 cm)
|
1.65 x 2.65 x 0.20 inches
(6.7 x 4.2 x 0.5 cm)
|
| Weight |
< 0.7 oz (< 20 g)
|
< 0.7 oz (< 20 g)
|
| Antenna
Connector |
MMCX receptacle
Optional integrated dipole available
|
MMCX receptacle
|
| Certification |
AC5124-10
|
AC5124-200
|
| Approvals |
Approved in the U.S., Canada and
Europe for portable, mobile and fixed/basestation applications
with antennas as specified.
|
Approved in the U.S. and Canada
for mobile and fixed/basestation applications.
|
| Safety |
Meets all safety and emissions
requirements.
|
Meets all emission requirements
but requires 32cm separation from the end-user to adhere to safety
standards.
|